The difference between the Iseo 1 grounding clamp and the Iseo 2 grounding clamp is:
La pinza di messa a terra ISEO 1 ha un solo contatto per la messa a terra, invece la pinza di messa a terra ISEO 2 has one grounding contact and one consent contact for electronic equipment.
Grounding for the dissipation of static electricity buildup.
Pinza ISEO 1 ATEX grounding clamp ISEO 1 in custody II 2GD Ex db IIC T6 Gb / Ex tb IIIC T85°C Db IP65 Ambient. Temp -20°/+55°C in compliance with standards EN IEC 60079-0, EN 60079-1 , EN 60079-31 (CESI 03 ATEX 101X approved) for potentially explosive atmospheres with the presence of group IIC gases and flammable dusts, equipped with re-opening – tearproof system.
Reliable, sturdy, handy and easy to use, the Iseo 1 ATEX grounding pliers are particularly suitable for equipping vehicles, trailers and tanks or for electrically grounding mixing tanks. They easily connect to any handhold , even in the presence of strong oxidation. Insulation voltage: 3kV – Rated current: 10A
Isolation voltage: 3kV - Rated current: 10A
ATEX grounding clamps connected to equipment for signaling and control
Grounding connected to signalling and control equipment. ISEO 2 ATEX grounding pliers with one ground contact and one consent contact for electronic equipment, both in II 2GD Ex db IIC T6 Gb / Ex tb IIIC T85°C Db IP65 Ambient Temp. -20°/+55°C in compliance with EN IEC 60079-0, EN 60079-1 , EN 60079-31 (CESI 03 ATEX 101X approved) for potentially explosive atmospheres with the presence of group IIC gases and flammable dusts.
Safe, easy to handle and simple to use, the ISEO 2 ATEX grounding pliers are the ideal equipment for tanker loading shelters equipped with electronic grounding signalling equipment. They can be easily connected to any handhold , even in the presence of strong oxidation. Insulation voltage: 3kV – Rated current: 10A.
This particular function is the main difference between Iseo 1 and Iseo 2.
Easily connectable to any grounding point, even in the presence of heavy oxidation. Isolation voltage: 3kV - Rated current: 10A.